The Unitron UDC-420M is the new and reliable way to power your aircraft. This 28V DC rectifier produces 425 amps continuous and 1,600 amps maximum, making it ideal for use in the hangar or ramp environment. This unit operates on 3-phase input voltage (50 or 60 Hz).
Highlights and Benefits
- Digital touchscreen display
- Over-voltage protection
- Under voltage protection
- Voltage regulation to 28.5V DC +/- 0.5 V at all times
- Output amperage can be limited to as low as 150 amps - fully adjustable
- Line drop compensation – accounts for voltage drop in the supply cable
- The only unit to meet 18" fire code regulations
- Half the weight of the competitor's model
Standard Features
- P55
- Certified to UL 1012
- Indoor/Outdoor (Hangar/Ramp)
- Use Automatic Input Line Monitoring
- 8000 Event Log / Diagnostics
- TCP/IP/Ethernet Interface (Modbus)
- 10% Power Regulation
- Internal Communication Ports - USB, RJ45 (Ethernet), RS485 (Modbus), & RS232
- External Communication Ports - RJ45 (Ethernet) & USB
- Emergency Power "OFF" Switch
- 18-Inch Hazard Area Clearance
- Voltage and Current Monitoring
- Elapsed Time Meter Access
- Front Panel Voltage Adjust
- Front Panel Summary Fault Indicators
- Input & Output Cable handle
- Input High Voltage Transient Protection
- Output Current Limit Adjust from 150 to the full rated current
- Multi-Language (Romanization) Display – English, French, German, Italian, Portuguese, Russian and Spanish, Others - Specify
Input
- Voltage: 208V to 240V and 380V to 480V, +/- 10%, 3 or 4 wire plus ground (Specify manual tap position at the time of order)
- Frequency: 50 to 60 Hz +/- 10%
- Phase Rotation: Any
- Protection: Over/under-voltage, loss of phase, overcurrent, short circuit. Voltage transient protection IAW IEEE C62.41.1, Location Cat. B/C
- Inrush Current: No greater than 100% of full load current
Output
- Full Rated Load: 425 amps continuous
- Engine Start Capacity (10% duty cycle): Adjustable up to 1,600 amps for 35 seconds or 2,000 amps for 30 seconds
- Overload (10% duty cycle): 600 amps for 1 hour 1000 amps for 1 minute
- Voltage: 28 VDC, 2 wire, grounded negative
- Voltage Regulation
- 100% continuous rated load and +/-10% input voltage ; +/- 0.5%
- No load to rated load with nominal input voltage; AW ISO 6858 and MIL-STD-704F
- Overload with nominal input voltage; See start mode curves
- Voltage Adjust: 28 VDC +/- 10%
- Current Limit Adjust: 150A to the full rated current
- Protection: Overload, short circuit, over-voltage and safety disconnect
- Power Regulation: 10%
Environmental
- Acoustical Noise: 65 dBA maximum at 5 ft. (1.5 m)
- Temperature Range: -40°C to 55°C
- EMI/RFI: Compatible with aircraft systems
- Relative Humidity: 10% to 95%, Non-Condensing
- Ingress of Water: Type 3RX, IP55
Mechanical Specs
- Dimensions: See image on listing.
- Weight: 340 lbs. (154 kg)
- Enclosure: NEMA 3RX Corrosion-Resistant
- Cooling: Forced Convection
Standards
- ISO 461-1/2 - Aircraft - Connectors for Ground Electrical Supplies
- ISO 1540 - Characteristics of aircraft electrical system
- ISO 6858 - Aircraft ground support electrical supplies
- MIL-STD-704F - Aircraft electric power characteristics
- MIL-STD-1472 - Human Engineering Design Criteria
Add-On Top Cable Rack Options Available for Longer Cable Lengths
- CR 1-12 (12" cable rack) - 180' max (option) of combined cable
- CR 1-9 (9" cable rack) - 120' max (option) of combined cable
- Cable handle (standard in unit) 120' of combined cable
Unitron Power Systems UDC-420M
$24,000.00Price